Model | S-100-5 | S-100-12 | S-100-15 | S-100-24 |
DC output voltage | 5V/20A | 12V/8.5A | 15V/7A | 24V/4.5A |
Wave and noise | 75mVp-p | 50mVp-p | 50mVp-p | 50mVp-p |
Inlet stability | +/-0.5% | +/-0.3% | +/-0.2% | +/-0.2% |
Load stability | +/-0.5% | +/-0.3% | +/-0.2% | +/-0.2% |
Efficiency | 78% | 81% | 84% | 84% |
Adjustable range for DC voltage | +/-10% | +/-10% | +/-10% | +/-10% |
AC input voltage range | 85~132VAC/170~264VAC Selected by switch 47~63Hz, 240-370VDC |
AC inrush current | Cold-start current 30A/115V 60A/230V |
Overload protection | 105%-150% hiccup mode, auto-recovery |
Over-voltage protection | |
Setup rise hold up time | 200ms 50ms 20ms |
Withstand voltage | I/P-O/P 1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
Isolation resistance | IP-O/P I/P-FG O/P-FG:500VDC/100MΩ |
Working temperature | -10~50ºC |
Safety standards | Design refer to GB4943, UL60950, EN60950 |
EMC standards | Design refer to GB9254, EN55022 Class B |
Weight | 0.65kg |
Size | 199*98*38mm |