Model | BDR-60W-5 | BDR-60W-12 | BDR-60W-15 | BDR-60W-24 |
DC output voltage | 5V/6.5A | 12V/4.5A | 15V/4A | 24V/2.5A |
Wave and noise | 50mVp-p | 50mVp-p | 50mVp-p | 50mVp-p |
Inlet stability | +/-0.5% | +/-0.5% | +/-0.5% | +/-0.5% |
Load stability | +/-1% | +/-0.5% | +/-0.5% | +/-0.5% |
Efficiency | 76% | 82% | 83% | 84% |
Adjustable range for DC voltage | +/-10% | +/-10% | +/-10% | +/-10% |
AC input voltage range | 85-264VAC 47-63Hz 124-370VDC |
AC inrush current | Cold-start current 18A/115VAC 36A/230V |
Overload protection | 105%-160% constant current limiting, auto-recovery |
Over-voltage protection | 115%-135% rated output voltage |
Setup rise hold up time | 100ms 30ms 60ms 230VAC at full load |
Withstand voltage | I/P-O/P 3KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
Isolation resistance | IP-O/P I/P-FG O/P-FG:500VDC/100MΩ |
Working temperature | -10~50ºC |
Safety standards | Design refer to GB4943, UL60950, EN60950 |
EMC standards | Design refer to GB9254, EN55022 Class B |
Weight | 0.3kg |
Size | 78*93*56mm |