Feature
1. Adopt DSP microprocessor of TI company in America and IPM intellegent module.
2. Space voltage vector SAPWM control, few harmonic output, low noise.
3. Effect is very good of stop of DC braking capacity from 0%-100%
4. Four kinds time of acceleration/decelaration which can setting arbitrarily of time 0.1 second to 999.9 seconds.
5. Six multi-functional terminals which can setting arbitrarity of 24 kinds of purpose
6. PLC running which can setting of 16' stage running frequency and time.
7. Built-in PID and funciton of speed setting on pulse coder.
8. RS485 communication control adopt the popular MODBUS communication protector.
9. Appearance size with subminiature +keypad design with simple.
Specification:
Phase no.: Single-phase
Input voltage: AC110V or 200V or 220V or 240V
Output voltage: AC110V & 220V
With fuse protector or with over current protector.
Application:
All the Electronic Equipments.
Remarks:
Custom-made specifications are acceptable.
Input voltage class | 220V | |||||
ZVF11-M/S… | 0004S2 | 00075S2 | 0015S2 | 0022S2 | ||
Applicable motor power(KW) | 0.4 | 0.75 | 1.5 | 2.2 | ||
Output | Output current | 2.3 | 4.5 | 7.5 | 10 | |
Maximum output voltage(V) | Three-phase 0~input voltage | |||||
Range of output frequency(Hz) | 0.0~400.00Hz | |||||
Input | Range of input voltage | 160~240V | ||||
Range of input power frequency | 50/60Hz+/-55Hz | |||||
Control characteristics | Control mode | SAPWM space vector control | ||||
Frequency resolution | Digital setting:0.01Hz; Analog setting: Maximum frequency: 0.1% | |||||
Torque characteristics | Adjustable from 0% to 20% | |||||
Overload capacity | 150% of the rated output current per minute | |||||
Acceleration/Deceleration time | Adjustable from 0.1 to 999.9 | |||||
Linear/Quadratic | ||||||
Running characteristics | Frequency setting signal | Panel control | Set by the key or the potentiometer on the panel | |||
External signal | Terminal 0~10V, 4~20Ma, 0~10KHz, UP/DOWN, 485 COM etc. | |||||
Operation setting signal | Panel Control | Set by key RUN or STOP | ||||
Extent signal | External FWD, REV and JOG operation, PLC operation and com operation | |||||
Multi-function input signal | Multi phase spped, counter, program run, VI/CI shifting and etc. | |||||
Multi-function output signal | Failure, running, counter arrival, frequency arrival program running | |||||
Analog output signal | Running frequency, output voltage, current, motor rotation | |||||
Other functions | AVR, overvoltage and current stall prevention, no reversal and etc. | |||||
Protecting functions | Overvoltage, overcurrent, under-voltage, overload, overheat, short circuit protection and etc. | |||||
Cooling mode | Forced air cooling | |||||
Ambient | Points of use | Attitude<1000m, indoor places without corrosive gas, liquid and etc. | ||||
External Environment | Temperature:-10~+45?; humidity<90%RH without condensing | |||||
Vibration | <0.5G |