Input voltage class | 220V |
ZVF11-M/S… | 0004S2 | 00075S2 | 0015S2 | 0022S2 |
Applicable motor power(KW) | 0.4 | 0.75 | 1.5 | 2.2 |
Output | Output current | 2.3 | 4.5 | 7.5 | 10 |
Maximum output voltage(V) | Three-phase 0~input voltage |
Range of output frequency(Hz) | 0.0~400.00Hz |
Input | Range of input voltage | 160~240V |
Range of input power frequency | 50/60Hz+/-55Hz |
Control characteristics | Control mode | SAPWM space vector control |
Frequency resolution | Digital setting:0.01Hz; Analog setting: Maximum frequency: 0.1% |
Torque characteristics | Adjustable from 0% to 20% |
Overload capacity | 150% of the rated output current per minute |
Acceleration/Deceleration time | Adjustable from 0.1 to 999.9 |
| Linear/Quadratic |
Running characteristics | Frequency setting signal | Panel control | Set by the key or the potentiometer on the panel |
External signal | Terminal 0~10V, 4~20Ma, 0~10KHz, UP/DOWN, 485 COM etc. |
Operation setting signal | Panel Control | Set by key RUN or STOP |
Extent signal | External FWD, REV and JOG operation, PLC operation and com operation |
Multi-function input signal | Multi phase spped, counter, program run, VI/CI shifting and etc. |
Multi-function output signal | Failure, running, counter arrival, frequency arrival program running |
Analog output signal | Running frequency, output voltage, current, motor rotation |
Other functions | AVR, overvoltage and current stall prevention, no reversal and etc. |
Protecting functions | Overvoltage, overcurrent, under-voltage, overload, overheat, short circuit protection and etc. |
Cooling mode | Forced air cooling |
Ambient | Points of use | Attitude<1000m, indoor places without corrosive gas, liquid and etc. |
External Environment | Temperature:-10~+45?; humidity<90%RH without condensing |
Vibration | <0.5G |